BAUR PHG 70

VLF test system

 Data interface

RS 232 optical

 Resolution

10 μA

 Frequency range

0.01 Hz to 1 Hz

 VLF square wave voltage

57 kV

 Direct current

70 kV, 10 mA
50 kV, 60 mA
20 kV, 90 mA

 Accuracy

1%

 Measurement range

0 to 120 mA

 Load range

> 10 nF (500 pF, Option)

 Accuracy

± 1% of measured value +1 x 10-4

 Resolution

1 x 10-5

 Measurement range

0.1 x 10-3 to 1000 x 10-3

 Automatic detection and compensation of leakage currents

1%

 Voltage range

1-38 kVrms truesinus®

 Input voltage

230 V (50/60 Hz), (200 to 264 V), 115 V (50/60 Hz), (100 to 140 V)

 Transmitting pulse

38 kVrms truesinus®

 DC voltage

+/- 70 kV

 Ambient temperature (operation)

0 °C to +45 °C

 Storage temperature

-20 °C to +60 °C

 Relative humidity

Non-condensing

 Dimensions (W x H x D)

483 x 623 x 775 mm (power unit)

 Weight

Power unit: approx. 160 kg, Total: 250 – 400 kg (version-dependent)

 Germanyes
 Englishyes
 Frenchyes
 Spanishyes
 Other languages on requestyes
 Hardware 
  PC

BAUR IPC, MS Windows

  Resolution

0.1 pC; 0.1 m

  Display

15.1” TFT

 Voltage measurement

1-38 kVrms truesinus®

 Measurement range

12,800 m (at 80 m/μs)

 Propagation speed

50-120 m/μs

 Sampling rate

10 ns (100 Msamples)

 PD background noise level

20 pC

 Accuracy of location

1% of the cable length

 

more products of interest